A complete recovery and maintenance solution for mineral-oil based turbine lubricants. SVR® targets and removes the dissolved varnish pre-cursors which are the cause of varnish. By removing these waste oxidation by-products, you restore the oils original solvency properties which forces any solid varnish deposits to be dissolved back into the oil where they are removed permanently.
*SVR® is a registered trademark of EPT CLEAN OIL.
58” (147 cm)
98” (249 cm) with crane
48” (122 cm)
26” (66 cm)
700 lbs (318 kg)
1.5” FNPT with locking ball valve
1” FNPT with locking ball valve
8,000 gal (30,000 liter) reservoir
Max 16,000 gal (60,000 liter) reservoir
SVR1200: HP107L18-VTM710-C-V
SVR2400: HP107L18-VTM710V
SVR1200X: no particulate filter included
SVR1200: ICB600524-V x 2
SVR2400: ICB600524-V x 4
SVR1200X: ICB600524-V x 2
Fluorocarbon + silicone
86°F to 176°F
(30°C to 80°C)
-4°F to 104°F
(-20C to 40C)
Carbon steel with industrial coating
ASME U Code optional
Carbon steel with industrial coating
Swagelok® stainless
TEFC, 56-145 frame
1-1.5 hp, 1150-1750 RPM
MSP (motor starter/protector) in an IP65, aluminum enclosure with short circuit and overload protection.
Cast iron, positive displacement gear pump with internal relief. Maximum pressure on pump inlet 15 psi (1 bar). Consult factory for higher pressures.
Full bypass at 90 psi (6.2 bar)
7-11 gpm
14-16 gpm
5 gpm (18.9 lpm) max
10 gpm (37.9 lpm) max
~40 cfm @ 80 psi
β3[C] ≥ 4000 particulate, insoluble oxidation by-product and water removal media
ICB® Ion-Exchange resin media for molecular removal of acids, varnish deposits, soluble oxidation by-products and dissolved metal ions from mineral based turbine oil.
Petroleum and mineral based fluids only (standard). For phosphate ester and other specified synthetic fluids, see FSA (page 108) or contact factory.
Select pneumatic powered unit (Power Option 00) or explosion proof NEC Article 501, Class 1, Division 1, Group C+D. Call for IEC, Atex or other requirements.