FSJL fluid conditioning skids are a total solution for managing aeroderivative jet lube oils susceptible to high thermal oxidative stress and coke deposit formation. FSJL prevents and reduces coke deposits that lead to variable geometry failures. Extend useful fluid life by removing the catalysts for oxidation; O2 contact, acid, oxidative coking precursors, dissolved metals, combustible gases, water, and varnish all while maintaining low ISO Codes. Specifically designed for MIL-L-23699 aeroderivative jet lube oils, the FSJL eliminates the contamination that leads to variable geometry failures.
Ideal for maintenance of aeroderivative jet lube oil and hydraulic systems.
58” (147 cm)
47.5” (121 cm)
31.5” (80 cm)
571 lbs (259 kg)
1” FNPT with ball valve
1” FNPT with ball valve
150 gal (560 liters)
300 gal (1,125 liters)
800 gal (3,000 liters)
1,600 gal (6,000 liters)
HP107L18-VTM710-C-V
FSJL05: ICB600504-J
FSJL1: ICB 600504-J x 2
FSJL2: ICB600524-J
FSJL4: ICB600524-J x 2
Fluorocarbon + silicone
86°F to 176°F
(30°C to 80°C)
-4°F to 104°F
(-20C to 40C)
Carbon steel with industrial coating
Carbon steel with industrial coating
TEFC, 56-145 frame
0.5 hp, 1450-1750 RPM
MSP (motor starter/protector) in an IP65, aluminum enclosure with short circuit and overload protection.
Cast iron, positive displacement gear pump with internal relief. Maximum pressure on pump inlet 15 psi (1 bar). Consult factory for higher pressures.
Full bypass at 150 psi (10 bar)
~40 cfm @ 80 psi2
< 1.2 SCFM
TMR-N2 - 601902
< 1.2 SCFM
TMR-N2 - 601902
< 2.0 SCFM
TMR-N2 - 601903
< 3.6 SCFM
TMR-N2 - 601904
β3[C] ≥ 4000 particulate, insoluble oxidation by-product and water removal media.
ICB® Ion-Exchange resin media for molecular removal of acids, gels and deposits, oxidation by-products and dissolved metal ions from polyol ester and other synthetic fluids.
Type II, MIL-L-23699, polyol ester base stock, synthetic turbo oils and polyol esters.
Select pneumatic powered unit (Power Option 00) or explosion proof NEC Article 501, Class 1, Division 1, Group C+D. Call for IEC, Atex or other requirements.