Ideal for sub-micron insoluble contamination removal in phosphate ester fluids in turbine EHC systems.
Remove fine particulates that are below the range of mechanical filters. Standard Electrostatic Oil Cleaner (EOC) systems are ineffective for phosphate ester fluid applications due to fluid conductivity restrictions. The ECR® is designed specifically to solve this dilemma.
* ECR, ICB, and TMR are registered trademarks of 1441413 Alberta Inc dba EPT Clean Oil
60” (152 cm)
64” (163 cm)
30” (62 cm)
680 lbs (308 kg)
3 gpm (11.4 lpm)
1-Collector element
2-ICB®
Ion-exchange Filters
1-High-efficiency Particulate Filter
Fluorocarbon
Weather resistant NEMA 4 enclosure
12,000 V
1/2HP, 56C Frame
1450-1750 RPM, TEFC
15 lbs (6.8 kg) per element
4,000 hrs (Collector), 1 month during clean up mode for the first three months and 6-12 months during maintenance mode determined by sample analysis (ICB® Filter), Differential Pressure (High Efficiency Particulate Filter)
6 psi (0.41 bar), 12.2 Hg (Vacuum)
<500 ppm for maximum efficiency
Phosphate ester based fire resistant fluids.